installation_guidelines
Table of Contents
Installation Guidelines
Recommended stages for a Wonder Controlz escape room installation.
Planning
- Define room layout, puzzle flow, and prop list
- Map sensors and effectors to I/O module outputs/inputs
- Determine how many I/O modules, media PCs, and lighting controllers are needed
- Plan CAN bus cable routing and power supply placement
Infrastructure
- Install one or more 24V industrial power supplies (see 24V SELV guidelines)
- Route the CAN bus cable (4 wires: 24V + GND + CAN_H + CAN_L) through the room
- Install 120 Ω termination resistors at both ends of the CAN bus
- Set up the local network (Ethernet) for media and lighting devices
- Minimum wire cross-section for all power and output wiring: 1 mm²
I/O Modules
- Mount I/O modules inside or next to props — keep sensor and effector cables short
- Connect sensors (reed switches, buttons, PIR, etc.) to digital inputs
- Connect effectors (locks, LEDs, motors, etc.) to PWM or servo outputs
- Set unique CAN addresses on each module using the front panel buttons
Media & Lighting Devices
- Deploy dedicated mini-PCs where needed for video (mpv-control) or additional audio
- Deploy er-lights hardware controllers for LED strips and DMX fixtures
- Connect all devices to the local network
Commissioning
All devices are delivered with software pre-installed and pre-configured. During commissioning:
- Verify network connectivity between the Main PC and all media/lighting devices
- Test CAN bus communication with all I/O modules
- Confirm audio outputs, video displays, and lighting controllers respond correctly
Game Programming
- Build the game scenario in Node-RED on the Main PC
- Node-RED uses visual, flow-based programming — connect nodes to define game logic
- Use the custom Wonder Controlz node palette for direct control of all devices
Testing & Tuning
- Run the room end-to-end
- Adjust timing, volumes, light effects, and difficulty
- Test edge cases: what happens when players skip a step, act out of order, or run out of time
Handover
- Establish the VPN connection for remote support
- Export the Node-RED flow as a backup
- Document any room-specific configuration (CAN addresses, media file locations, special wiring)